ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF METFORMIN AND SAXAGLIPTIN
HTML Full TextANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF METFORMIN AND SAXAGLIPTIN
Mahnoor Fatima * and S. Roshan
Azad College of Pharmacy, Moinabad, Hyderabad, Telangana, India.
ABSTRACT: The present study aims to develop a verse phase HPLC method for the simultaneous estimation of Metformin and Saxagliptin. In bulk and pharmaceutical dosage form and to validate the proposed method in accordance with ICH guidelines for the intended analytical application. Multiple trials were run to Metformin and Saxagliptin, get eluted with good peak symmetric properties. Mobile phase Phosphate buffer: Methanol: Acetonitrile (40:5:55), Column Hypersil silica and flow rate 1.0ml, detection wavelength at 233nm, column temperature 300C and diluents Water: Methanol (50:50). Column Hypersil silica and flow rate 1.0 ml, detection wavelength at 210 nm conditions were finalized as an optimized method. This method was validated for Stability Data, System suitability, Precision, Linearity, Accuracy, Robustness, Ruggedness, LOD, and LOQ. System suitability parameters were studied by injecting the standard five times, and results were well under the acceptance criteria. Linearity study was carried out between 25% to 150% levels, r2 value found 0.999. By using the above method, assay of the marketed formulation was carried out 99.63% was present. So, this method can be used to estimate Metformin and Saxagliptin in Pharmaceutical dosage form for routine analysis purposes.
Keywords: RP-HPLC, Metformin, Saxagliptin, Antidiabeticdrug, Percentage purity
INTRODUCTION: Metformin is an oral antidiabetic drug and is a chemical, 1, 1-dimethyl biguanide hydrochloride 27. It has high efficacy, safety profile, beneficial cardiovascular and metabolic effects and therapeutic benefit associated with other antidiabetic drugs. Hence, this drug is included in first-line therapy to treat patients with type 2 diabetes mellitus 28. The main action of Metformin is to decrease fasting plasma glucose levels and is achieved by suppressing excessive hepatic glucose production and improving glucose clearance.
It is the principal component in combination therapies intended for diabetes and is frequently used in high doses of about 500 to 850 mg 27. Saxagliptin is also an oral antidiabetic drug and is belongs to new dipeptidyl peptidase-4 (DPP-4) inhibitor class of drugs 29. Chemical name is (1S, 3S, 5S) – 2 - [(2S) – 2 – amino – 2 - (3 - hydroxy-1-adamantyl) acetyl]-2-azabicyclo [3.1.0] hexane-3-carbonitrile 30. It is used for the treatment of type II diabetes in combination with Metformin, a sulphonylurea 29.
HPLC 9, 13 is a modern technique; it is a much more reliable and reproducible method for standardizing both single and compound formulation. HPLC is a separation technique based on a stationary phase and a liquid mobile phase. Separations are achieved by partition, adsorption, or ion exchange process, depending upon the size of the stationary phase used. Reversed-phase HPLC (RP-HPLC or RPC) has non-polar stationary and aqueous, moderately polar mobile phases. One common stationary phase is silica treated with RMe2SiCl, where R is a straight-chain alkyl group such as C18H37 or C8H17. With these stationary phases, retention time is longer for more non-polar molecules, while polar molecules elute more readily. RPC 19 operates on the principle of hydrophobic forces, which originate from the high symmetry in the dipolar water structure and play the most important role in all processes in life science. RPC allows the measurement of these interactive forces. The binding of the analyte to the stationary phase is proportional to the contact surface area around the non-polar segment of the analyte molecule upon association with the ligand in the aqueous eluent 1.
Literature Review: R. Pravin Kumar et al., have developed a simple, economical, sensitive RP-HPLC method for the simultaneous estimation of Metformin and saxagliptin in tablets. The method was carried out on C18 column (5 μm, 25 cm x 4.6 mm, i.d) using phosphate buffer (pH 5.0), acetonitrile, and methanol in the ratio 75:15: 10 respectively as a mobile phase at a flow rate of 1.5mL/min. The wavelength for Metformin and saxagliptin at 225 nm was found to be appropriate. The retention time of Metformin and saxagliptin was found to be 5.65 and 6.20 min, respectively. The developed method is rapid and sensitive, which can be used to estimate a combination of Metformin and saxagliptin in pharmaceutical dosage forms.
V. M. S. Bhagavanji et al., developed an isocratic, reversed phase-liquid-chromatographic method was developed for the quantitative determination of Metformin and Saxagliptin in combined-dosage form. A thermo hypersil BDS C8 (250*4.6*5μ) column with mobile phase containing water pH 3.0 adjusted with orthophosphoric acid: methanol was used in the (70: 30, v/v) ratio. The flow rate was 1.0 mL/min, the column temperature was 30°C, and effluents were monitored at 241 nm. The retention times of Metformin and Saxagliptin were 4.7min and 6.8 min, respectively. The correlation coefficient for Metformin and Saxagliptin was found to be 1 and 0.999, respectively. The proposed method was validated concerning linearity, accuracy, precision, specificity, and robustness. Recovery of Metformin and Saxagliptin in formulations was found to be in the range of 98-103% and 99-103%, respectively confirming the non-interferences of the excipients in the formulation due to its simplicity, rapidness and high precision. The method was successfully applied to the estimation of Metformin and Saxagliptin in the combined dosage form.
Objective: In the present study, the combination of Metformin and Saxagliptin was selected. The extensive literature survey revealed that there are very few methods reported for the simultaneous estimation of these drugs in other combinations. Hence an attempt was made to develop a specific, precise, accurate, linear, simple, rapid, validated, and cost-effective HPLC method for the simultaneous estimation of Metformin and Saxagliptin in combined dosage forms.
MATERIALS AND METHODS: A simple reverse phase HPLC method was developed to determine Metformin 22 and Saxagliptin present in pharmaceutical dosage forms of 500 mg and 5mg. Column 9 used Hypersil Silica (250 x 4.6 mm, packed with 5μm) in an isocratic mode with mobile phase Buffer: Acetonitrile (55:45) was used. The flow rate was 1.0ml/ min, and effluent was monitored at 210.
Instrument:
HPLC System: Water alliance 2695 separation modules with PDA detector 22 connected to empower software.
Method Development: Based on drug solubility 11 and Pka Value following conditions has been used to develop the method for simultaneous estimation of Metformin and Saxagliptin 16
Optimized Method:
Buffer: Accurately weighed 1.36gm of potassium dihydrogen phosphate in 1000ml of Volumetric flask (0.01M) add about 900ml of milli-Q water and sonicate to dissolve then makeup to 1000ml add 0.5ml of Triethylamine.PH 6.2 with dil Orthophosphoric acid solution.
Mobile Phase:
Buffer and methanol: water (40:5:55).
Chromatographic Conditions:
Flow rate: 1 ml/min
Column: Hypersil Silica, 250 x 4.6 mm, 5m.
Detector wave length: 210nm
Column temperature: 30°C
Injection volume: 10mL
Run time: 10 min
Diluent: Water: Methanol (50:50)
Standard Preparation: Accurately Weighed and transferred 50 mg of Metformin and 10mg of Saxagliptin working Standards into a 10 ml clean dry volumetric flask, add 7ml of diluent, sonicated for 5 min and makeup to the final volume with diluents.
Sample Preparation: 5 tablets were weighed, and calculate the average weight of each tablet was; then the weight equivalent to 20 tablets was transferred into a 250 mL volumetric flask, 150mL of diluent added and sonicated for 25 min; further, the volume was made up with diluent and filtered. From the filtered solution, 1ml was pipetted out into a 10 ml volumetric flask and made upto 10ml with diluents 13.
S. no. | Peak name | RT | Area | %Area | UPS plate count | UPS tailing |
1 | Saxagliptin | 5.365 | 397138 | 18.20 | 5537 | 1.18 |
2 | Metformin | 7.468 | 1785303 | 81.80 | 7946 | 1.61 |
FIG. 1: CHROMATOGRAM ASSAY
Assay Method: Assay of the marketed formulation was carried out by injecting sample 14 corresponding to equivalent weight into HPLC system 15-25. And percent purity was found out by following formulae. Calculate the percentage purity of Metformin and Saxagliptin present in tablet using the formula: Spl area Std. Dil. Fac Avg. Wt of Tab Potency of Std
Assay = ---- X---- X ----X
Std area Spl. Dil. Fac L.C, Spl area – Sample Peak area, Std area – Standard Peak area, Std. Dil. Fac, Spl. Dil. Fac, Avg. Wt. of Tab, L.C, Potency of Std.
Selection of Solvent: Metformin and Saxagliptin are marketed as combined dosage formulations. different solvents are used for the solubility of drugs, it was found that both the drugs are freely soluble in acetonitrile 15.
Selection of Mobile Phase: The proposed method for estimation Metformin and Saxagliptin required adequate resolution of the two drug peaks in the chromatogram illustrated in Fig. 1. Several solvent systems were tried to obtain good optimum resolution.
Selection of Wavelength for Detection: Standard solutions of Metformin and Saxagliptin were scanned in the wavelength range of 200nm-400nm using Buffer, Methanol taken in the ratio 55:45 v/v as mobile phase.
Preparation of Buffer: Accurately weighed 1.36gm of Potassium dihydrogen orthophosphate was transferred into a 1000mlof Volumetric flask, about 900ml of milli-Q water was added and sonicate 9 to degassed and finally make up the volume with water. Finally, pH is adjusted to 6.2 with a dilute orthophosphoric acid solution.
Mobile Phase: Buffer Methanol were taken in the ratio 55:45v/v. Peaks of Metformin and Saxagliptin were well resolved with the solvent system of Buffer and Methanol in the ratio of 55:45 v/v.
Determination of Retention Time:
Standard Stock Solution of Metformin Accurately 50 mg of Metformin was weighed into a clean and dry 10 ml volumetric flask, dissolved with sufficient volume of diluent and sonicate for 5min. The volume made up to 10ml with diluent (5000µg/ml).
Standard Stock Solution of Saxagliptin: Accurately 10 mg of Saxagliptin was weighed into a clean and dry 10 ml volumetric flask, dissolved with sufficient volume of diluent and sonicate for 5min. The volume made up to 100ml with diluent (1000µg/ml).
Procedure: 2 ml of standard stock solution of Metformin (5000µg/ml) and 0.1ml of standard stock solution of saxgliptin (1000 µg/ml) are transferred in to a 10 ml volumetric flask and the volume made with diluent. The resulting solution was sonicated for 10 min and injected. The retention time, peak area and peak resolution were observed and the chromatogram is presented in Fig. 1.
TABLE 1: ASSAY METHOD DEVELOPMENT
Flow rate | 1ml/min |
Column | Hypersil Silica, 250 x 4.6 mm, 5m. |
Detector wave length | 210nm |
Column temperature | 30°C |
Injection volume | 10mL |
Run time | 10 min |
Diluent | Water: Methanol (50:50) |
Mobile phase | Buffer: Methanol (55:45) |
Validation of HPLC Method Developed for Simultaneous Determination of Metformin and Saxagliptinin Bulk and Tablet Dosage Form: The HPLC method developed was validated by performing the various method validation parameters like LOD, LOQ, linearity and range, precision, specificity, accuracy, robustness 17, and system suitability parameters given in Table 2, 3, 4, 5, 10, 11, 12.
Precision Determination: The precision of the analytical method is determined by assaying a sufficient number of samples, and the relative standard deviation is calculated.
Method:
Preparation of Standard Stock Solution: Accurately weigh 50 mg of Metformin and 10mg of Saxagliptin and transferred into 10 ml volumetric flask and dissolved and volume was made up with diluents.
To 1 ml of the above solution is diluted to 10 ml with diluent to obtain the concentration of 1000 μg/ml of Metformin and 10μg/ml of Saxagliptin. Like six solutions were prepared individually and injected Six times into the HPLC and recorded the chromatograms.
Method Precision: Six Sample solutions were prepared individually from Metformin and Saxagliptin stock solution, as per methodology, and injected each solution into HPLC as given in Table 2.
Acceptance Criteria: % RSD Should not be more than 2.0%.
TABLE 2: RESULTS OF PRECISION
Sample no. | Sample (MET) | % Assay | Sample (SAX) | % Assay |
1 | 394019 | 99.46 | 1789461 | 99.82 |
2 | 392734 | 99.14 | 1785736 | 99.77 |
3 | 391339 | 98.79 | 1782127 | 99.67 |
4 | 397992 | 100.47 | 1785378 | 100.52 |
5 | 392832 | 99.16 | 1783720 | 100.01 |
6 | 393064 | 99.22 | 1785882 | 99.89 |
AVG | 393663 | 99.37 | 1785384 | 99.95 |
S.D | 2288.2 | 0.57762 | 2464.5 | 0.30426 |
% RSD | 0.581 | 0.58 | 0.138 | 0.30 |
TABLE 3: SYSTEM PRECISSION
System Precission | Metformin Areas | Saxagliptin Areas |
1 | 393864 | 1789461 |
2 | 398285 | 1785736 |
3 | 397478 | 1782127 |
4 | 399012 | 1785378 |
5 | 389781 | 1783720 |
6 | 396097 | 1785882 |
AVG | 395753 | 1785384 |
SD | 3445.7 | 2464.58 |
%RSD | 0.9 | 0.14 |
System Suitability: This parameter ensures that the analytical system is working properly and can give accurate and precise results. Solutions of Metformin and Saxagliptin were injected, and the parameter like theoretical plates per column and parameter of column was calculated from the following chromatogram given in Fig. 4.
TABLE 4: SYSTEM SUITABILITY PARAMETERS
Parameters | Metformin | Saxagliptin | Acceptance criteria |
Theoretical plates | 7715 | 5623 | More than 2000 |
Tailing factor | 1.23 | 1.65 | Less than 2 |
Retention time | 5.1 | 7.6 | More than 2 |
Report: The system suitability parameters were determined for Metformin and Saxagliptin and were found to be within the acceptance criteria given in Table 4.
Specificity: This parameter was performed to assess and ensure that the impurities, degraded products and diluents do not affect the samples analyzed.
Metformin and Saxagliptin were injected into the system and chromatograms were recorded and presented below in Fig. 2.
FIG. 2: CHROMATOGRAM OF DILUENTS
FIG. 3: CHROMATOGRAM OF PLACEBO
S. no. | Peak name | RT | Area | %Area | UPS plate count | UPS tailing |
1 | Saxagliptin | 5.180 | 429400 | 18.69 | 5142 | 1.27 |
2 | Metformin | 7.756 | 1868275 | 81.31 | 7964 | 1.55 |
FIG. 4: CHROMATOGRAM OF METFORMIN AND SAXAGLIPTIN STANDARD
Report: The chromatograms of standards Metformin and Saxagliptin. Samples were fully resolved, and there is no interference from diluents, excipients, and impurities with the peaks of Metformin and Saxagliptin as shown in Fig. 4.
Limit of Detection: This parameter was performed by the developed HPLC method for the determination of Metformin and Saxagliptinand the chromatograms obtained are presented below.
TABLE 5: LOD REPORT OF METFORMIN AND SAXAGLIPTIN
Drug | Limit of Detection(μg/ml) |
Metformin | 0.48μg/ml |
Saxagliptin | 0.21μg/ml |
Report: LOD for Metformin and Saxagliptin were found to be 0.48μg/ml and 0.21μg/ml, respectively, as shown in Table 5.
Limit of Quantification: LOQ parameter was performed to know the lowest amount of analyte in the sample, which can be determined and quantified with precision and accuracy.
TABLE 6: LOD REPORT OF METFORMIN AND SAXAGLIPTIN
Drug | Limit of Quantification(μg/ml) |
Metformin | 1.45μg/ml |
Saxagliptin | 0.65μg/ml |
Report: The limit of quantification of Metformin and Saxagliptin were found to be 1.45μg/ml and 0.65μg/ml, respectively, as shown in Table 6.
Linearity: The linearity parameter was performed to ensure that the test results are directly proportional to the concentration of the analyte sample. For the linearity, 100% of each of the working standard solutions of Metformin and Saxagliptin were injected into the HPLC system.
The peak area and concentration were plotted to get a standard calibration curve. The correlation coefficient and regression coefficient were calculated. The results obtained are tabulated in Table 7.
Preparation of Linearity Solutions:
Preparation of 25% Solution (250ppm & 2.5ppm): from stock solution, 0.025 ml was taken in 10 ml volumetric flask, and volume was made up with diluents.
Preparation of 50% Solution (500ppm & 5ppm): from solution, 0.50 ml was taken in 10 ml volumetric flask, and volume were made up with diluent.
Preparation of 75% Solution (750ppm & 7.5ppm): from solution 0.75 ml was taken in 10 ml volumetric flask, and volume was made up with diluent.
Preparation of 100% Solution (1000ppm & 10ppm): from solution 1.0 ml was taken in 10 ml volumetric flask, and volume was made up with diluent.
Preparation of 125% Solution (1250ppm & 12.5ppm): from solution 0.125 ml was taken in 10 ml volumetric flask, and volume was made up with diluent.
Preparation of 150% Solution (1500ppm & 15ppm): from solution, 0.15 ml was taken in 10 ml volumetric flask, and volume was made up with diluent.
TABLE 7: LINEARITY SAMPLE
S. no. | Pipetted from stock (mL) | Volume of flask (mL) | Concentration in ppm(Met) | Concentration in ppm (Saxa) | %Linearity Level |
1 | 0.025 | 10 | 250 | 2.5 | 25 |
2 | 0.5 | 10 | 500 | 5 | 50 |
3 | 0.75 | 10 | 750 | 7.5 | 75 |
4 | 1 | 10 | 1000 | 10 | 100 |
5 | 1.25 | 10 | 1250 | 12.5 | 125 |
6. | 1.5 | 10 | 1500 | 15 | 150 |
TABLE 8: LINEARITY OF METFORMIN
S. no. | Concentration (μg/ml) | Area |
1 | 250 | 527715 |
2 | 500 | 993507 |
3 | 750 | 1481077 |
4 | 1000 | 1960220 |
5 | 1250 | 2463740 |
6 | 1500 | 2962524 |
TABLE 9: LINEARITY OF SAXAGLIPTIN
Sl. no. | Concentration (μg/ml) | Area |
1 | 2.5 | 116944 |
2 | 5 | 223826 |
3 | 7.5 | 322138 |
4 | 10 | 433036 |
5 | 12.5 | 548500 |
6. | 15 | 656144 |
FIG. 5: LINEARITY CURVE FOR METFORMIN
FIG. 6: LINEARITY CURVE FOR SAXAGLIPTIN
TABLE 10: CORRELATION COEFFICIENT AND % CURVE FITTING FOR METFORMIN AND SAXAGLIPTIN
Parameters | Results (n=6) | |
Metformin | Saxagliptin | |
Linearity range | 250-1500 mg/ml | 2.5-15mg/ml |
Slope | 1960 | 43439 |
Intercept | 13433 | 2860 |
Correlation coefficient | 0.999 | 0.999 |
The proposed method is found to be linear at a concentration of 250-1500 mg/ml for Metformin and 2.5-15mg/ml for Saxagliptin in Fig. 5 and 6 and Table 8, 9.
The correlation coefficient and % curve fitting for Metformin and Saxagliptin were found to be 0.999, 99.9%, and 0.999, 99.9%, respectively, given in Table 10, which is well within the acceptance criteria limits.
Accuracy: This parameter is performed to determine the closeness of test results with that of the true value, which is expressed as % recovery as shown in Fig. 7, 8, 9. The difference between the theoretical added amount and the practically achieved amount is called the accuracy of the analytical method. Accuracy was determined at three different levels 50%, 100% and 150% of the target concentration in triplicate, as shown in Table 11, 12.
TABLE 11: RESULTS OF RECOVERY STUDIES FOR METFORMIN
Level % | No | Recovery (%) | Mean Recovery (%) | SD | RSD (%) |
50% | 1 | 100.49 | 100.44
|
0.0862
|
0.09
|
2 | 100.34 | ||||
3 | 100.50 | ||||
100% | 1 | 99.99 | 99.97 | 0.0396 | 0.04
|
2 | 99.93 | ||||
3 | 100.00 | ||||
150% | 1 | 99.13 | 99.41
|
0.2432 | 0.24
|
2 | 99.54 | ||||
3 | 99.56 |
TABLE 12: RESULTS OF RECOVERY STUDIES FOR SAXAGLIPTIN
Level % | No | Recovery (%) | Mean Recovery (%) | SD | RSD (%) |
50% | 1 | 100.28 | 100.27
|
0.1207
|
0.12
|
2 | 100.14 | ||||
3 | 100.38 | ||||
100% | 1 | 101.73 | 101.57
|
0.1886
|
0.19
|
2 | 101.63 | ||||
3 | 101.36 | ||||
150% | 1 | 100.64 | 100.58
|
0.1480 | 0.15
|
2 | 100.41 | ||||
3 | 100.69 |
FIG. 7: CHROMATOGRAM FOR RECOVERY STUDIES-50% LEVEL 1, 2, 3.
PEAK NAME: SAXAGLIPTIN
S. no. | Peak name | RT | Area | UPS plate count | UPS tailing |
1 | Saxagliptin | 5.177 | 198637 | 5653 | 1.23 |
2 | Saxagliptin | 7.181 | 198352 | 5807 | 1.20 |
3 | Saxagliptin | 5.187 | 198827 | 5864 | 1.22 |
PEAK NAME: METFORMIN
S. no. | Peak name | RT | Area | UPS plate count | UPS tailing |
1 | Metformin | 7.688 | 989820 | 5653 | 1.52 |
2 | Metformin | 7.695 | 989558 | 5807 | 1.51 |
3 | Metformin | 7.704 | 898957 | 5864 | 1.51 |
FIG. 8: CHROMATOGRAM FOR RECOVERY STUDIES-100% LEVEL 1, 2, 3
PEAK NAME: SAXAGLIPTIN
S. no. | Peak name | RT | Area | UPS plate count | UPS tailing |
1 | Saxagliptin | 5.162 | 402984 | 5970 | 1.22 |
2 | Saxagliptin | 7.163 | 402620 | 5972 | 1.22 |
3 | Saxagliptin | 5.170 | 401547 | 5953 | 1.23 |
PEAK NAME: METFORMIN
S. no. | Peak name | RT | Area | UPS plate count | UPS tailing |
1 | Metformin | 7.689 | 1788769 | 7953 | 1.61 |
2 | Metformin | 7.697 | 1767696 | 8244 | 1.57 |
3 | Metformin | 7.711 | 1759036 | 8293 | 1.55 |
FIG. 9: CHROMATOGRAM FOR RECOVERY STUDIES-150% LEVEL 1, 2, 3
PEAK NAME: SAXAGLIPTIN
S. no. | Peak name | RT | Area | UPS plate count | UPS tailing |
1 | Saxagliptin | 5.119 | 588837 | 5873 | 1.25 |
2 | Saxagliptin | 5.152 | 589100 | 5940 | 1.25 |
3 | Saxagliptin | 5.154 | 589323 | 5948 | 1.25 |
PEAK NAME: METFORMIN
S. no. | Peak name | RT | Area | UPS plate count | UPS tailing |
1 | Metformin | 7.682 | 3060185 | 7577 | 1.64 |
2 | Metformin | 7.690 | 3071217 | 7598 | 1.64 |
3 | Metformin | 7.697 | 3071745 | 7537 | 1.63 |
Report: The mean percentage recovery for Metformin and Saxagliptin was found to be between 98.95-102.3% given in Fig. 7, 98.94-102.66 % given in Fig. 8 and 98.98-101.66 % in Fig. 9 respectively, which are well within the limit and hence the method was found to be accurate.
CONCLUSION: System suitability parameters were studied by injecting the standard five times, and results were well under the acceptance criteria. Linearity study was carried out between 25% to 150% levels, r2 value found 0. 999. By using the above method, assay of the marketed formulation was carried out 99.63% was present. So, this method can be used for the estimation of Metformin and Saxagliptin in Pharmaceutical dosage form for routine analysis purposes.
ACKNOWLEDGMENT: The authors are thankful to Central Library, Azad College of Pharmacy, for providing literature.
CONFLICTS OF INTEREST: The authors declare that they have no conflicts of interest concerning this article.
Authors’ Contributions: Mahnoor Fatima conceived of and wrote the manuscript. Roshan S. edited the paper. Both authors read and approved the final manuscript.
REFERENCES:
- Ewing GW: Instrumental Methods of Chemical Analysis. McGraw Hill Publishing M Company INS 2nd Ed 1960: 3.
- Lurie SI, Wittwer D and John JR: HPLC in Forensic Chemistry. Marcel Dekker Incoporated 1983.
- Skoog DA, West DM and Holler FJ: Fundamentals of Analytical Chemistry. Saunders College Publishing New York 6th Ed 713.
- Jeffery GH, Bassett J, Medham J and Denney RC: Vogel’s Textbook of Quantitative Chemical Analysis. English Language Book Society/ Longman 5th Ed 1989; 668.
- International Conference on Harmonization, Validation of Analytical Procedures. Methodology Federal Register 1996; 1-8.
- International Conference on Harmonization, Draft Guideline on Validation of Analytical Procedures, Definitions and Terminology, Federal Register 1995; (26): 11260.
- United State Pharmacopoeia, Vol. I & II, Asian edition, UnitedPharmacopeial Convention, Inc., Rockville 2000; 2149.
- United State Pharmacopoeia, Vol. I & II, Asian edition, UnitedPharmacopeial Convention, Inc., Rockville 2000; 1923.
- Chatwal GR and Anand SK: In instrumental method of chemical analysis. 5th Edn 2005; 2: 107.
- Sharma BK: In instrumental method of chemical analysis. 15th Edn 1996; 453.
- Beckett AH and Stenlake JB: In practical pharmaceutical chemistry. 4th Edn 2002; 2: 85.
- Willard M, HH, Dean, JR and JA: In; instrumental method of analysis. 6th Edn 1986; 504.
- Ravi Shankar S: In; text book of pharmaceutical analysis. 3rd Edn 1999; 13-1.
- Remington the science and practice of pharmacy. 20th Edition 2000; 1: 587.
- Mashru R and Koshti N: Development and validation of UV-Spectrophotometric and RP-HPLC method for simultaneous estimation of Metformin and Doxycycline in bulk and synthetic mixture. Journal of Drug Delivery and Therapeutics 2021; 11(4): 26-35.
- Sivagami B, Purushotham A, Sikdar P, Chandrasekar R and Niranjan MB: A Validated Method for the Simultaneous Estimation of Linagliptin and Metformin in Tablet Dosage Forms by RP-HPLC. Research J Pharm and Tech 2020; 13(3): 1266-1270. doi: 10.5958/0974-360X.2020.00233.4
- Bagadane SB and Jadhav PB: Development and validation of RP-HPLC method for simultaneous estimation of metformin hydrochloride and glipizide in bulk and pharmaceutical dosage form. JDDT 2019 [cited 30Oct.2021];9(3-s):146-55. Available from: http://jddtonline.info/index.php/jddt/article/view/2813
- El-Bagary RI: Liquid Chromatographic Determination of Linagliptin in Bulk, in Plasma and in its Pharmaceutical Preparation. International Journal of Biomedical Science 2012; 8(3): 209.
- Balamurugan K, Mishra Kirtimaya & Swaminathan Suresh: Simultaneous estimation of linagliptin and metformin hcl in human plasma by RP-HPLC method. International Research Journal of Pharmacy 2019; 10: 167-170.
- Elsheikh R, Shassan W, Youssef E, Yhamdi A, Ahmedbadahdah N and Esaalzuhiri MAA: elfetouh gouda. “Development and validation of rapid stability-indicating high-performance liquid chromatography method for the determination of linagliptin and empagliflozin in pure and dosage forms. Asian Journal of Pharmaceutical and Clinical Research 2020; 13(4): 172-7. doi:10.22159/ajpcr. 2020.v13i4.36939.
- Ramakrishna, Badikela & Mondal and Sumanta: A review of analytical methods for determination of type- ii antidiabetic drugs in pharmaceuticals and biological matrices. Asian Journal of Pharmaceutical and Clinical Research 2021; 69-76. 10.22159/ajpcr. 2021.v14i1.40049.
- Khoja SS and Patel LJ: “Development and Validation of New RP-HPLC Method for the Estimation of Antidiabetic Drugs Metformin Hydrochloride and Gemigliptin in Combined Pharmaceutical Dosage Form. Journal of Pharmaceutical Research International 2021; 33(30): 149-160. doi: 10.9734/jpri/2021/v33i30B31649.
- Gaikwad AV and PreetiKhulbe: A Comprehensive Review on various HPLC based Analytical techniques used for the Estimation of SGLT2 inhibitors type of Antidiabetic drugs in various dosage forms. Research J Pharm and Tech 2020; 13(9): 4484-4490. doi: 10.5958/0974-360X.2020.00791.
- Dhaneshwaret SR: Validated HPTLC Method for Simultaneous Estimation of Metformin Hydrochloride, Atorvastatin and Glimepiride in Bulk Drug and Formulation. J Anal Bioanal Tech 1: 109. doi:10.4172/2155-9872.1000109.
- Majithia RH, AkrutiKhodadiya and Patel VB: Spectrophotometric method development and validation for simultaneous estimation of Anagliptin and Metformin HCl BY Q - Absorption ratio method in synthetic mixture 2020; 6- 5.
- https://www.sciencedirect.com/science/article/pii/S2405844020307003)
- Indian Pharmacopeia. Government of India ministry of health and family welfare. Indian Pharmacopeia Commission 2018.
- Havele S and Dhaneshwar S: Development and Validation of a HPLC Method for the Determination of Metformin Hydrochloride, Gliclazide and Piogliglitazone Hydrochloride in Multicomponent Formulation. Webmed Central Pharmaceutical Sciences 2010; 1: Article ID: WMC001078.
- Rojas LBA and Gomes MB: Metformin: An Old but Still the Best Treatment for Type 2 Diabetes. Diabetology and Metabolic Syndrome 2013; 5: 1-15.
- http://dx.doi.org/10.1186/1758-5996-5-6
- Kumar P, Vasudevan R and Deecaraman M: A Validated RP-HPLC Method for Simultaneous Estimation of Metformin and Saxagliptin in Tablets. Rasayan Journal Chemistry 2012; 5: 137-141.
- Srinivasa Rao, Rama Chandran P, Murali DK and Srinivasu S: Stability Indicating Isocratic Reverse Phase HPLC Method with PDA Detector for the Estimation of Saxagliptin in Bulk Drugs and in Its Formulation. International Journal of Pharma Sciences 2013; 3: 333-42.
How to cite this article:
Fatima M and Roshan S: Analytical method development and validation for simultaneous estimation of metformin and saxagliptin. Int J Pharm Sci & Res 2022; 13(6): 2497-07. doi: 10.13040/IJPSR.0975-8232.13(6).2497-07.