SIMULTANEOUS ESTIMATION OF CIPROFLOXACIN AND METRONIDAZOLE IN BULK AND TABLET FORMULATION BY UV SPECTROPHOTOMETRY
HTML Full TextSIMULTANEOUS ESTIMATION OF CIPROFLOXACIN AND METRONIDAZOLE IN BULK AND TABLET FORMULATION BY UV SPECTROPHOTOMETRY
A. Veeshma, S. Priyanka, K. Praveen Kumar and K. Sirisha *
Department of Pharmaceutical Analysis, Vaagdevi College of Pharmacy, Ramnagar, Hanmakonda, Warangal - 506001, Telangana, India.
ABSTRACT: Three simple and economical UV-spectrophotometric methods have been developed and validated for simultaneous estimation of ciprofloxacin (CIP) and metronidazole (MET) in a tablet dosage form using distilled water as a green solvent. The proposed methods were; simultaneous equation method (method A), Q-absorbance ratio method (method B), and area under curve method (method C). λmax of CIP & MET in distilled water were found to be 271 nm and 320 nm, respectively. The isoabsorptive point was observed at 290 nm. The linearity was obtained in the concentration range of 1-9 μg/ml, and 2-18 μg/ml for CIP and MET respectively by methods A, B & C. Validation parameters were carried out. All three methods were found to be linear, accurate, precise, and specific. Good results were achieved using distilled water as solvent due to its greater solubility, reproducible readings with maximum absorbance. Among the three methods, method C was found to be the most sensitive. Hence, this method can be recommended for the routine analysis of this drug combination.
Keywords: |
UV, Simultaneous equation method, Q-absorbance ratio method, Ciprofloxacin, Metronidazole
INTRODUCTION: Ciprofloxacin (CIP) is chemically 1-cyclopropyl-6-fluoro-1, 4-dihydro-4-oxo-7-(1-piperazinyl)-3-quinoline carboxylic acid Fig. 1. It is a fluoroquinolone antibiotic useful for the treatment of various infections caused by Gram-positive, Gram-negative organisms and against Mycobacterium tuberculosis. The bactericidal action of CIP results from inhibition of the enzymes topisomerase 2 (DNA gyrase) and topisomerase 4, which are required for bacterial DNA replication, transcription repair, and recombination 1, 2. Metronidazole (MET) is designated chemically as 2-(2-methyl-5-nitro-1H-imidazole-1-yl) ethan-1-ol Fig. 2.
It is a prodrug unionized and the most useful antiprotozoal nitroimidazole derivative. It has been found to possess efficacy against obligate anaerobic bacteria due to their ability to intracellularly reduce MET to its active form, which then covalently binds to DNA, disrupts its helical structure, inhibiting the bacterial nucleic acid synthesis and results in bacterial cell death 3, 4.
A survey of literature has revealed several analytical methods for the determination of CIP in pharmaceutical dosage form and biological fluids, including spectrophotometry 5-9, spectrofluorimetry 10, HPLC 11-13, potentiometry 14, electrical micro-titration 15, and HPTLC 16. CIP in admixtures with MET 17 and ampicillin has been determined by NMR 18. HPLC methods either with fluorescence detection or coupled with mass spectrometry (LC/MS) for determination of CIP in human plasma 19, 20, and by SPE-UHPLC-PDA 21 have also been published. MET has been determined by several methods involving spectrophotometry 22 and HPLC 23-26. For CIP & MET, recently, more and more work has also been done on the use of HPLC-DAD 27 and ultra-performance liquid chromatography with tandem mass spectrometry (UPLC/MS/MS) 28, 29. So, far to the best of our knowledge, no UV spectrophotometric analytical method is available in the literature for simultaneously analyzing these two drugs by the area under curve method using distilled water as a green solvent. It was felt necessary to develop simple, precise, and rapid methods for quantitative determination of CIP and MET. Therefore, this paper describes the development and validation of methods to simultaneously quantify these two drugs by three simple UV spectrophotometric methods, i.e., simultaneous equation method, Q-absorbance ratio method, and area under curve method in bulk and tablet formulation and to compare the results. The proposed methods were optimized and validated as per ICH guidelines 30.
MATERIALS AND METHODS:
Instruments: Absorbance measurements were made on double beam UV-visible spectro-photometer, model 1800, Shimadzu, Japan; with software UV Probe 2.10 and 1 cm matched quartz cells. Standard and sample drugs were weighed by keroy weigh balance (KRT 12HS). Ultrasonicator (1.5 l) was used to sonicate the standard and formulation samples.
Chemicals: Gift samples of active pharmaceutical ingredients CIP and MET were provided by MSN Labs, Hyderabad, Telangana, India, respectively. The formulation CIPFUN – M (CIP - 500 mg and MET - 250 mg) was purchased from Hanmakonda local market. Reagents like acetonitrile, methanol and distilled water used in analytical methods selection were of HPLC grade from Merck, Mumbai, India. Standard methanol and sodium hydroxide of desired normality were prepared.
Solubility Test: The solubility of CIP and MET were determined by dissolving the drugs in different solvents like methanol, distilled water, aqueous sodium hydroxide solution, dilute hydrochloric acid, etc. and solvent with a high degree of solubility is selected for experimental work. From the above solvents, distilled water is selected for analysis because both drugs were completely soluble.
Preparation of Standard Stock Solution: Standard stock solutions of both drugs were prepared separately by dissolving accurately weighed 10 mg of CIP and 10 mg of MET into 100 ml clean dry volumetric flasks.
20 ml of distilled water was added for complete dissolution, and the volume was made up to the mark with distilled water (stock solution). 5 ml of CIP and 5ml of MET were pipetted from the above stock solutions into 10 ml volumetric flasks and diluted up to the mark with distilled water.
Preparation of Working Standard Solutions: From the above stock solutions, desired concen-trations were prepared by transferring specific volume to separate 10 ml volumetric flasks and volume was made up to 10 ml with purified distilled water.
Sample Solution Preparation: Accurately weighed a quantity of tablet powder equivalent to 5 mg of CIP and MET samples into a 100 ml clean dry volumetric flask.
Added 20 ml of distilled water to dissolve it completely and made the volume up to the mark with distilled water (stock solution). It was sonicated for 15 min and filtered with Whatman filter paper. From the above filtrate, a volume of 10 ml of CIP and MET was pipetted into a 100 ml volumetric flask and diluted up to the mark with distilled water to get 5 µg/ml sample solution.
Method Development:
Selection of Suitable Detection Wavelength: UV scan of CIP and MET was done individually, and both were overlayed upon each other to get the required wavelength. The maximum wavelength of CIP and MET were found to be 271 & 320 nm, respectively. The isoabsorptive point was found to be 290 nm Fig. 3 and Fig. 4. These wavelengths were effective in the determination of both the drugs at a time.
FIG. 3: OVERLAY SPECTRUM OF CIP AND MET
FIG. 4: OVERLAY SPECTRUM OF TABLET FORMULATION (CIP AND MET)
Simultaneous Equation Method (Method A): 1 μg/ml solutions of CIP and MET were prepared separately in distilled water, and the solutions were scanned against blank in the entire UV range to determine the λmax values. Clear peaks were observed at 271 nm for CIP and 320 nm for MET. Hence these wavelengths were chosen as λmax values for each drug, respectively. The absorbances were measured at both wavelengths. Standard solutions of CIP and MET in the concentration range 1- 5 µg/ml were prepared, and the absorbance of these solutions was measured at 271 and 320 nm. Calibration curves were plotted to verify Beer’s law and the absorptivity values calculated at the respective wavelengths for both the drugs. If a sample contains two absorbing drugs (X= CIP and Y=MET) each of which absorbs at the λ - max of the other (λ1 and λ2), it may be possible to determine both the drugs by the simultaneous equation method. Criteria for obtaining maximum precision is that below-mentioned ratio should lie outside the range 0.1-2.0
(A2/A1) / (ax2/aX1) and (aY2/aY1) / (A2/A1)
The information required is (I) the absorptivities of X at λ1 and λ2 are aX1and aX2 (II), the absorptivities of Y at λ1 and λ2 are aY1and aY2 (III), and the absorbance of the diluted sample at λ1 and λ2 are A1 and A2. Let Cx and Cy be the concentration of X and Y respectively in the sample. The absorbance of the mixture is the sum of the individual absorbances of X and Y. Two simultaneous equations as below were formed using these absorptivity values A (1%, 1 cm)
At λ1, A1= ax1bCx+ay1bCy …. (1)
At λ2, A2= ax2bCx+ay2 bCy……. (2)
For measurements in 1 cm cells b=1 Rearrange eq. (2)
Cy = A2 - ax2 Cx / ay2
Substituting for Cy in eq (1) and rearranging
CX = (A1 ay2 - A2 ay1) / (ax1 ay2 - ax2 ay1)
Cy = (A2 ax1 – A1 ax2) / (ax1 ay2 - ax2 ay1)
Where, Cx and Cy are the concentrations of CIP and MET measured in gm/100 ml in sample solutions, A1 and A2 are absorbances of mixture at selected wavelengths 271 and 320 nm, respectively.
Q-absorbance Ratio Method / Q-Analysis (Method B): The absorbance ratio method is a modification of the simultaneous equation procedure. It depends on the property that, for a substance, which obeys Beer’s law at all wavelengths, the ratio of absorbance at any two wavelengths is a constant value independent of concentration or path length.
For example, two dilutions of the same substance give the same absorbance ratio A1/A2. In the USP, this ratio is referred to as the Q value. In the quantitative assay of two components in admixture by the absorbance ratio method, absorbencies are measured at two wavelengths, one being the λmax of one of the components (λ2) and the other being wavelength of equal absorptivity of two components (λ1) i.e., an isoabsorptive point.
A series of standard solutions of CIP and MET in the concentration range of 1-5 µg/ml were prepared, and the absorbance of these solutions was measured at 290 nm (isoabsorptive point).
Calibration curves were plotted to verify Beer’s law and the absorptivity values calculated at the respective wavelength for both the drugs. The absorptivity values were reported. The concen-tration of two drugs in a mixture was calculated by using the following equations:
Cx = Qm – Qy / Qx – Qy × A1 / ax1……5
Cy = Qm – Qx / Qy – Qx × A1 / ay1….6
Where, Qm = A2/A1 Qx = ax2/ax1 Qy = ay2/ay1 A1 is absorbance of mixture at isobestic point i.e., 290 nm. A2 is absorbance of mixture at 320 nm, λmax of MET. Ax1 and ax2 represent absorptivities of CIP at 271nm & 320 nm. ay1and ay2 denotes absorptivities of MET at 271nm &320 nm. Cx and Cy are the concentration of CIP and MET.
Area Under Curve Method (Method C): The method C is used in case of the presence of broad spectra and absence of sharp peaks. This method is based on the calculation of the integrated value of absorbance between the selected two wavelengths.
This wavelength range is chosen depending on several trials performed to obtain a good linear relationship between area under curve and concentration. This method utilizes two wavelength ranges.
From the overlain spectra of both the drugs, the area under the curve is determined at both selected wavelength ranges 250-285 nm for CIP & 306-336 nm for MET within the above-selected wavelength ranges, the area under curve was determined for both drugs (CIP & MET-10 µg/ml & 16 µg/ml) and sample solutions were analyzed and concentration of CIP & MET in sample solution were calculated using “Cramel’s Rule” and “Matrix method”.
CM = XNλ1-λ2 AUCλ3-λ4-XNλ3-λ4 AUCλ1-λ2 / XNλ1-λ2 XMλ3-λ4 - XNλ3-λ4 XMλ1-λ2
CN = XMλ1-λ2 AUCλ3-λ4 - XMλ1-λ2AUCλ1-λ2 / XNλ1-λ2 XMλ3-λ4 - XNλ3-λ4 XMλ1-λ2
Where, CM&CN: concentration of components M and N in a sample. AUCM λ1-λ2: area under the curve for component M at wavelength ranges λ1-λ2 AUCM λ3-λ4: area under the curve for component M at wavelength ranges λ3-λ4 AUCN λ1-λ2: area under the curve for component N at wavelength ranges λ1-λ2 AUCN λ3-λ4: area under the curve for component N at wavelength ranges λ3-λ4.
X λ1-λ2 = AUC λ1-λ2 / Conc. in g/l
X λ3-λ4 = AUC λ3-λ4 / Conc. in g/l
AUC λ1-λ2 = AUCM λ1-λ2 + AUCN λ1-λ2
AUC λ3-λ4 = AUCM λ3-λ4 + AUCN λ3-λ4
The overlay spectrum of CIP and MET by the area under the curve method was presented in Fig. 5 and Fig. 6.
FIG. 5: OVERLAY SPECTRUM OF AREA UNDER CURVE SAMPLE FORCIP
FIG. 6: OVERLAY SPECTRUM OF AREA UNDER CURVE SAMPLE FOR MET
Validation of Proposed Methods (Methods A, B and C): The method was validated according to ICH guidelines.
Linearity: Accurately weigh and transfer 10 mg of CIP and 10 mg of MET working standard into a 100 ml clean dry volumetric flask. Add about 20 ml of distilled water to dissolve it completely and make the volume upto the mark with distilled water to get 100 µg/ml of stock solution. The method was validated for linearity by taking standard in level–I, level–II, level–III, level–IV, level–V (Linearity results for CIP and MET). Linearity was plotted among absorbance and concentration, and the response was found to be linear over the range of 1-10 µg/ml for CIP and 2- 20 µg/ml for MET of targeted concentration.
Preparation of level–I (1 ppm of CIP & 2 ppm of MET), level–II (2 ppm of CIP & 4 ppm of MET), level–III (3 ppm of CIP & 6 ppm of MET), level–IV (4 ppm of CIP & 8 ppm of MET) level–V (5 ppm of CIP & 10 ppm of MET) was carried out. Then absorbance was measured at three wavelengths. A graph of absorbance versus concentration in µg/ml (on X-axis concentration and Y-axis Peak absorbance) was plotted and calculated the correlation coefficient.
Accuracy (Recovery Studies): It is the closeness of agreement between the true value and found value is expressed as % recovery. It is determined by calculating % recovery. To ascertain the accuracy of the proposed methods, recovery studies were carried out by standard addition method at three different levels according to ICH guidelines. A series of solutions of CIP and MET at 80 %, 100 %, and 120 % of the standard preparation in the ratio of the formulation were prepared and checked for accuracy by determining the % recovery. Recovery samples are prepared in triplicate at each level, the samples at different levels and the percentage mean recovery for CIP and MET were calculated by using the formula
% Recovery = Amount found/amount taken x 100
The absorbance for standard solution, Accuracy-80 %, Accuracy-100 %, Accuracy-120 % solutions was measured. Calculated the amount found added for CIP & MET and calculated the individual recovery and mean recovery values.
Precision: Precision is the degree of repeatability of the analytical method under normal operational conditions. The repeatability, inter-day precision, and intraday precision were studied by comparing the assays by performing replicates of six on the same day (morning, afternoon, evening) and three different days, respectively. The results documented as standard deviation and % RSD.
% RSD = SD/Mean × 100
Where, SD is the standard deviation.
Precision studies were performed in triplicate at three different concentration levels covering the entire linearity range for CIP (1, 5, 9 µg/ml) and for MET (2, 10, 18 µg/ml).
Limit of Detection (LOD) and Limit of Quantification (LOQ): The detection limit of an individual analytical procedure is the lowest amount of analyte in the sample, which can be detected but not necessarily quantitated as an exact value. The quantification limit of an individual analytical procedure is the lowest amount of analyte in the sample, which can be quantitatively determined with suitable precision and accuracy. The LOD and LOQ of the proposed method were determined by using the calibration curve.
The formulae for LOD & LOQ are:
LOD = 3.3 σ / S
LOQ = 10 σ / S
Where, σ is mean standard deviation of y-intercepts of regression lines, S is slope of the standard curve.
RESULTS AND DISCUSSION: In the present work, we developed three UV spectroscopic methods and validated them as per ICH guidelines. UV-spectrophotometric methods have superiority over HPLC methods for being simple, rapid, cost-effective, and time-saving. Regression analysis of the Beer plots showed a good correlation in the concentration ranges of 1.0–9.0 μg/ml (CIP) & 2–18 μg/ml (MET) for methods A, B, and C using distilled water as a universal green medium Tables 1, 2 and 3 Fig. 7 to Fig. 12. Results were found to be linear in the concentration range of level I, II, III, IV, and V of CIP and MET with r² values for methods A, B, and C of 0.998, 0.997,0.997 (CIP), and 0.998,0.996,0.998 (MET), respectively.
Regarding method A, the highest % recoveries for CIP and MET were found to be 99.75 % and 94.5 %, respectively. For method B, the highest % recoveries for CIP and MET were found to be 99.6 % and 100 %, respectively. In method C, the highest % recoveries for CIP and MET were 103.5 % and 104.8 %,, respectively Table 4. The interday and intraday precision for CIP and MET were found to be <2% in Table 5, 6, 7, and 8.
The LOD and LOQ for CIP and MET results are shown in Table 9. Amongst the three methods, the lowest LOD and LOQ values for CIP and MET were observed in method C. The LOD and LOQ values obtained by method B for CIP (0.09 µg/ml and 0.28 µg/ml) and MET (0.07µg/ml and 0.22µg/ml) were found to be less than the earlier reports on their simultaneous estimation method by Q-absorbance ratio method in methanol. The validation parameters of CIP and MET are summarized in Tables 10 and 11, respectively. The developed methods have several advantages over the earlier reported spectrophotometric methods for simultaneous determination of CIP and MET, like the area under curve method (method C) is simpler, sensitive, accurate, and precise. The novelty of the method lies in making use of an economical green solvent like distilled water instead of using methanol, as reported in the previous method.
TABLE 1: LINEARITY RESULTS FOR CIP AND MET BY METHOD A
S. no. | CIP | MET | ||
Concentration (µg/ml) | Absorbance* | Concentration (µg/ml) | Absorbance* | |
01 | 1 | 0.108±0.001 | 2 | 0.127±0.001 |
02 | 2 | 0.213±0001 | 4 | 0.228±0.001 |
03 | 3 | 0.292±0.003 | 6 | 0.345±0.001 |
04 | 4 | 0.394±0.002 | 8 | 0.448±0.003 |
05 | 5 | 0.472±0.001 | 10 | 0.564±0.001 |
06 | 6 | 0.581±0.002 | 12 | 0.676±0.003 |
07 | 7 | 0.675±0.001 | 14 | 0.811±0.004 |
08 | 8 | 0.764±0.002 | 16 | 0.921±0.001 |
09 | 9 | 0.897±0.002 | 18 | 0.997±0.003 |
*Data represents mean ± SD (n=3).
TABLE 2: LINEARITY RESULTS FOR CIP AND MET BY METHOD B
S. no. | CIP | MET | ||
Concentration (µg/ml) | Absorbance* | Concentration (µg/ml) | Absorbance* | |
01 | 1 | 0.030±0.002 | 2 | 0.101±0.003 |
02 | 2 | 0.053±0.001 | 4 | 0.156±0.001 |
03 | 3 | 0.074±0.002 | 6 | 0.224±0.002 |
04 | 4 | 0.094±0.001 | 8 | 0.287±0.004 |
05 | 5 | 0.118±0.003 | 10 | 0.335±0.003 |
06 | 6 | 0.138±0.001 | 12 | 0.401±0.001 |
07 | 7 | 0.154±0.002 | 14 | 0.457±0.002 |
08 | 8 | 0.182±0.002 | 16 | 0.536±0.002 |
09 | 9 | 0.201±0.001 | 18 | 0.586±0.002 |
*Data represents mean ± SD (n=3).
TABLE 3: LINEARITY RESULTS FOR CIP AND MET BY METHOD C
S. no. | CIP | MET | ||
Concentration (µg/ml) | Absorbance* | Concentration (µg/ml) | Absorbance* | |
01 | 1 | 1.120±0.002 | 2 | 0.321±0.001 |
02 | 2 | 1.733±0.001 | 4 | 0.545±0.002 |
03 | 3 | 2.652±0.002 | 6 | 0.863±0.003 |
04 | 4 | 3.374±0.001 | 8 | 1.143±0.001 |
05 | 5 | 4.321±0.001 | 10 | 1.457±0.001 |
06 | 6 | 4.987±0.003 | 12 | 1.748±0.002 |
07 | 7 | 5.732±0.001 | 14 | 2.129±0.001 |
08 | 8 | 6.565±0.002 | 16 | 2.326±0.002 |
09 | 9 | 7.719±0.001 | 18 | 2.569±0.001 |
*Data represents mean ± SD (n=3).
TABLE 4: % RECOVERIES OF CIP AND MET FOR METHOD A, B AND C.
Method | CIP | MET | |||||
Amount Added
(µg/ml) |
Amount Found* (μg/ml) | % Recovery* | Amount Added
(µg/ml) |
Amount Found* (μg/ml) | % Recovery* | ||
Method A | 4 | 3.99±0.01 | 99.75±0.212 | 4 | 3.11±0.03 | 77.75±0.510 | |
5 | 4.93±0.02 | 98.6±0.238 | 5 | 4.01±0.02 | 80.2±0.420 | ||
6 | 4.92±0.02 | 82.9±0.241 | 6 | 5.67±0.01 | 94.5±0.411 | ||
Method B | 4 | 3.01±0.03 | 75.25±0.422 | 4 | 3.07±0.02 | 76.75±0.530 | |
5 | 4.98±0.02 | 99.6±0.002 | 5 | 4.88±0.02 | 97.6±0.328 | ||
6 | 5.67±0.03 | 94.5±0.246 | 6 | 6.00±0.01 | 100±0.120 | ||
Method C | 4 | 3.22±0.02 | 80.5±0.502 | 4 | 4.04±0.03 | 101±0.110 | |
5 | 4.29±0.02 | 85.8±0.438 | 5 | 5.24±0.04 | 104.8±0.320 | ||
6 | 6.21±0.01 | 103.5±0.322 | 6 | 5.90±0.03 | 98.33±0.239 | ||
*Values given in the table are the mean ± SD of three replicate experiments.
TABLE 5: INTRADAY PRECISION FOR CIP
Standard (CIP) | Method A* (271 nm) | Method B* (290 nm) | Method C* (250-285 nm) |
Sample–1 | 0.4134±0.0008 | 0.1623±0.0006 | 6.1109±0.0006 |
Sample–2 | 0.4143±0.0009 | 0.1638±0.0008 | 6.0103±0.0007 |
Sample–3 | 0.4123±0.0006 | 0.1632±0.0006 | 6.1064±0.0006 |
%RSD | 0.19 | 0.38 | 0.76 |
*Values given in the table are the mean ± SD of six observations.
TABLE 6: INTRADAY PRECISION FOR MET
Standard (CIP) | Method A* (320 nm) | Method B* (290 nm) | Method C* (306-336 nm) |
Sample–1 | 0.6013±0.0049 | 0.1508±0.1516 | 2.1214±0.0095 |
Sample–2 | 0.6129±0.0080 | 0.1527±0.1606 | 2.1415±0.099 |
Sample–3 | 0.6042±0.0090 | 0.1514±0.0577 | 2.1215±0.0069 |
%RSD | 0.81 | 0.50 | 0.44 |
*Values given in the table are mean ± SD of six observations.
TABLE 7: INTERDAY PRECISION FOR CIP
Standard (CIP) | Method A* (271nm) | Method B* (290 nm) | Method C* (250-285 nm) |
Sample–1 | 0.3247±0.0019 | 0.1341±0.0007 | 4.3075±0.0038 |
Sample–2 | 0.3256±0.0055 | 0.1342±0.0008 | 4.3035±0.0040 |
Sample–3 | 0.3212±0.0045 | 0.1356±0.0006 | 4.3129±0.0047 |
%RSD | 0.58 | 0.52 | 0.08 |
*Values given in the table are mean ± SD of six observations.
TABLE 8: INTERDAY PRECISION FOR MET
Standard (CIP) | Method A* (320 nm) | Method B* (290 nm) | Method C* (306-336 nm) |
Sample–1 | 0.5243±0.0013 | 0.7023±0.0001 | 1.6028±0.0045 |
Sample–2 | 0.5226±0.0030 | 0.7095±0.0003 | 1.6111±0.0056 |
Sample–3 | 0.5210±0.0004 | 0.7119±0.0016 | 1.6023±0.0077 |
%RSD | 0.25 | 0.57 | 0.24 |
*Values given in the table are mean ± SD of six observations.
TABLE 9: LOD & LOQ FOR CIP AND MET
Method | CIP | MET | ||
LOD (µg/ml) | LOQ (µg/ml) | LOD (µg/ml) | LOQ (µg/ml) | |
Method A | 0.15 | 0.16 | 0.07 | 0.23 |
Method B | 0.09 | 0.28 | 0.07 | 0.22 |
Method C | 0.01 | 0.04 | 0.02 | 0.09 |
TABLE 10: VALIDATION RESULTS FOR CIP
S. no. | Parameter | Method A | Method B | Method C |
01 | Wavelength (nm) | 271 | 290 | 250-285 |
02 | Linearity (µg/ml) | 1-10 | 1-10 | 1-10 |
03 | Regression equation | y= 0.96x+0.005 | y=0.021x+0.006 | y=0.821x+0.124 |
04 | (y = mx + c)* | |||
Correlation coefficient (r2) | 0.998 | 0.997 | 0.997 | |
05 | Intraday precision (% RSD) | 0.19 | 0.38 | 0.76 |
06 | Interday precision (% RSD) | 0.58 | 0.52 | 0.08 |
07 | % Recovery (Accuracy) | 99.75 | 99.6 | 103.5 |
08 | LOD (µg/ml) | 0.15 | 0.09 | 0.01 |
09 | LOQ (µg/ml) | 0.16 | 0.28 | 0.04 |
*Where y = absorbance and x = concentration, y = mx + c
TABLE 11: VALIDATION RESULTS FOR MET
S. no. | Parameter | Method A | Method B | Method C |
01 | Wavelength (nm) | 320 | 290 | 306-336 |
02 | Linearity (µg/ml) | 2-20 | 2-20 | 2-20 |
03 | Regression equation | y=0.056x+0.006 | y=0.031x+0.024 | y=1.727x+0.959 |
04 | (y = mx + c)* | |||
Correlation coefficient (r2) | 0.998 | 0.996 | 0.998 | |
05 | Intraday precision (% RSD) | 0.81 | 0.50 | 0.44 |
06 | Interday precision (% RSD) | 0.25 | 0.57 | 0.24 |
07 | % Recovery (Accuracy) | 94.5 | 100 | 104.8 |
08 | LOD (µg/ml) | 0.07 | 0.07 | 0.02 |
09 | LOQ (µg/ml) | 0.23 | 0.22 | 0.09 |
*where y = absorbance and x = concentration, y = mx + c
CONCLUSION: The two-drug combination: CIP/MET which is used for the treatment of systematic infections, can be simply analyzed by the adopted rapid, accurate, precise, and specific spectrophotometric methods through simultaneous equation, Q-absorbance ratio, an area under a curve and validated as per ICH guidelines. The developed spectrophotometric methods are considered to be suitable for application in quality control units where economy and time are very important.
The proposed spectrophotometric methods can estimate each drug without interference from the other without prior separation in comparison to HPLC methods which may require some effort to reach to the best chromatographic conditions for their separation. As compared to HPLC methods which require preliminary preparations for the chromate-graphic system before a run, the suggested spectrophotometric methods are considered to be time-saving techniques. Also, they are considered to be more economical where there is no need for expensive solvents in comparison to other reported chromatographic methods, distilled water being the only solvent used throughout the whole experiment. Further, sophisticated equipment is not needed, but instead, simple software programs are used. All the proposed methods were found to be linear, accurate, cost-effective, precise, specific, simple, and practical. The results of the recovery studies performed show the high degree of accuracy of the proposed methods. Amongst the three methods, the area under the curve (method C) was found to be most sensitive. Hence this method can be recommended for the routine quality control analysis of this drug combination.
ACKNOWLEDGEMENT: The authors are thankful to the Principal and Management of Vaagdevi College of Pharmacy, Warangal, for providing the necessary facilities in carrying out this work.
CONFLICTS OF INTEREST: All authors declare that they have no conflict of interest.
REFERENCES:
- Pham TDM, Ziora ZM and Blaskovich MAT: Quinolone antibiotics. Medicinal Chemistry Communications 2019; 10(10): 1719-39.
- Dhiman P, Arora N, Thanikachalam PV and Monga V: Recent advances in the synthetic and medical perspective of quinolones: A review. Bioorganic Chemistry 2019; 92: 103291.
- Petersen MW, Perner A, Jonsson AB, Bahador M, Sjövall F and Møller MH: Empirical metronidazole for patients with severe bacterial infection: A systematic review with meta-analysis and trial sequential analysis. Acta Anaesthesiologica Scandinavica 2019; 63(6): 802-13.
- Leitsch D: A review on metronidazole: an old warhorse in antimicrobial chemotherapy. Parasitology 2017; 146 (9): 1-12.
- Mahrouse MA and Elkady EF: Validated spectro-photometric methods for the simultaneous determination of ciprofloxacin hydrochloride and metronidazole in tablets. Chemical and Pharmaceutical Bulletin 2011; 59(12): 1485-93.
- Patel NV and Prajapati AM: Q-absorbance ratio spectrophotometric method for the simultaneous estimation of ciprofloxacin and metronidazole in their combined dosage form. Journal of Pharmaceutical Science and Bioscientific Research 2012; 2(3):118-22.
- Attia KAM, Nassar MWI, El-Zeiny MB and Serag A: Zero order and signal processing spectrophotometric techniques applied for resolving interference of metronidazole with ciprofloxacin in their pharmaceutical dosage form. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy 2016; 154: 232-36.
- Zareh MM, Saad MZ, Hassan WS, Elhennawy ME and Sebaiy MM: Validation of spectrophotometric method for determination of esomeprazole and ciprofloxacin in their pure and dosage forms. International Journal of Pharmaceutical Sciences and Developmental Research 2020; 6(1): 001-5.
- Obaydo RH and Sakur AA: Fingerprint spectro-photometric methods for the determination of co-formulated otic solution of ciprofloxacin and fluocinolone acetonide in their challengeable ratio. Journal of Analytical Methods in Chemistry 2019; 2019: 8919345.
- Saeed AMA and Salih ES: Indirect Spectrofluorometric method for the determination of cefotaxime sodium, ciprofloxacin hydrochloride and famotidine in pharmaceuticals using bromate-bromide and acriflavine dye. Baghdad Science Journal 2020; 17 (1): 66-77.
- Vella J, Busuttil F, Bartolo NS, Sammut C, Ferrito V, Serracino-Inglott A, Azzopardi LM and LaFerla G: A simple HPLC–UV method for the determination of ciprofloxacin in human plasma. Journal of Chromatography B 2015; 989: 80-85.
- Shehada A, Abdelwahed W and Sakur AA: An echo-friendly and validated RP-HPLC method for simultaneous determination of ciprofloxacine HCl and fluocinolone acetonide in bulk and dosage forms. Research Journal of Pharmacy and Technology 2020; 13(2): 715-18.
- Vybíralová Z, Nobilis M, Zoulova J, Kvetina J and Petr P: High-performance liquid chromatographic determination of ciprofloxacin in plasma samples. Journal Pharmaceutical and Biomedical Analysis 2015; 37(5): 851-58.
- Sakur AA, Dabbeet HA and Noureldin I: Novel drug selective sensors for simultaneous potentiometric determination of both ciprofloxacin and metronidazole in pure form and pharmaceutical formulations. Research Journal of Pharmacy and Technology 2019; 12(7): 3377-84.
- Zhang XZ, Huang MS, Yang QQ, Ding DS, Zhao J, Yang WR and Qu KM: Simple and cost-effective determination of ciprofloxacin hydrochloride by electrical micro-titration. Chinese Chemical Letters 2017; 28(7): 1406-12.
- Zhang D, Armour E and Sherma J: Development of quantitative HPTLC-densitometry methods following a model approach for transfer of TLC screening methods for pharmaceutical products of cefixime, cefuroxime axetil, cephalexin. H2O, ciprofloxacin HCl, levofloxacin and metronidazole. Acta Chromatographi 2017; 29(4): 484-86.
- Oli AN, Ibeabuchi MU, Enweani IB and Emencheta SC: Pharmaceutical quality of selected metronidazole and ciprofloxacin infusions marketed in south eastern Nigeria. Drug Health Patient Safety 2020; 12: 103-12.
- Reinscheid UM: Direct determination of ciprofloxacin in admixtures with metronidazole and ampicillin by NMR. Jo of Pharm and Biomedical Analysis 2006; 40(2): 447-49.
- Sousa J, Alves G, Fortuna A, Pena A, Lino C and Falcão A: Development and validation of a fast isocratic liquid chromatography method for the simultaneous determination of norfloxacin, lomefloxacin and ciprofloxacin in human plasma. Biomedical Chromatography 2011; 25 (5): 535-41.
- Choudhury H, Gorain B, Paul A, Sarkar P, Dan S, Chakraborty P and Pal TK: Development and validation of an LC-MS/MS-ESI method for comparative pharmacokinetic study of ciprofloxacin in healthy male subjects. Drug Research Stuttgart 2017; 67(2): 94-102.
- Ferrone V, Cotellese R, Cichella A, Raimondi P and Carlucci M: Meropenem and ciprofloxacin in complicated gastric surgery for cancer patients: A simple SPE-UHPLC-PDA method for their determination in human plasma. Biomedical Chromatography 2019; 33(3): 4450.
- Mishra AK, Kumar A, Mishra A and Mishra HV: Development of ultraviolet spectroscopic method for the estimation of metronidazole benzoate from pharmaceutical formulation. Journal of Natural Science Biology and Medicine 2014; 5(2): 261-64.
- Kubodera M, Tokumura T and Machida Y: Determination of metronidazole in a rat stomach by HPLC for obtaining basic data of the eradication therapy of Helicobacter pylori. J of Pharmaceutical Analysis 2012; 2(5): 378-81.
- Kumar YS, Sivaprasad P and Ashok KA: RP-HPLC method development and validation for simultaneous quantitative estimation of metronidazole and nalidixic acid in tablets. International Journal of Pharmacy and Pharmacuetical Sciences 2015; 7(2): 367-71.
- Maslarska V, Tsvetkova B, Peikova L and Bozhanov S: HPLC method for simultaneous determination of metronidazole and preservatives in vaginal gel formulation. Acta Chromatographica 2018; 30(2): 127-30.
- Bozhanov S, Maslarska V, Tsvetkova B and Peikova L: Simultaneous determination of some 5-nitroimidazole derivatives and ciprofloxacin by high performance liquid chromatography. Indian Journal of Pharmaceutical Education and Research 2018; 52(4): 23-28.
- Walczak-Skierska J, Szultka-Młyńska M, Pauter K and Buszewski B: Study of chromatographic behavior of antibiotic drugs and their metabolites based on quantitative structure-retention relationships with the use of HPLC-DAD. Journal of Pharmaceutical and Biomedical Analysis 2020; 184:113187.
- Magréault S, Leroux S, Touati J, Storme T and Jacqz-Aigrain E: UPLC/MS/MS assay for the simultaneous determination of seven antibiotics in human serum–Application to pediatric studies. Journal Pharmaceutical and Biomedical Analysis 2019; 174: 256-62.
- El-bagary R, El-Zaher AA, Elkady E and Mandour AA: Simultaneous determination of ciprofloxacin hydro-chloride and metronidazole in spiked human plasma by ultra performance liquid chromatography-tandem mass spectroscopy. Journal of Applied Pharmaceutical Science 2016; 6 (03): 041-47.
- International Conference of Harmonization. Validation of analytical procedures: Text and methodology. Geneva, Switzerland: ICH Q2 [R1]; 2005.
How to cite this article:
Veeshma A, Priyanka S, Kumar PK and Sirisha K: Simultaneous estimation of ciprofloxacin and metronidazole in bulk and tablet formulation by UV-spectrophotometry. Int J Pharm Sci & Res 2021; 12(4): 2247-56. doi: 10.13040/IJPSR.0975-8232.12(4).2247-56.
All © 2013 are reserved by the International Journal of Pharmaceutical Sciences and Research. This Journal licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 3.0 Unported License.
Article Information
42
2247-2256
842
854
English
IJPSR
A. Veeshma, S. Priyanka, K. P. Kumar and K. Sirisha *
Department of Pharmaceutical Analysis, Vaagdevi College of Pharmacy, Ramnagar, Hanmakonda, Warangal, Telangana, India.
ragisirisha@gmail.com
03 April 2020
19 August 2020
05 September 2020
10.13040/IJPSR.0975-8232.12(4).2247-56
01 April 2021