Posted by admin on Nov 1, 2014 in |
A simple, rapid and precise stability indicating reverse phase high performance liquid chromatographic method has been developed for simultaneous estimation of Miglitol and Metformine Hydrochloride in their tablet dosage form. Chromatography was performed on a Phenomenex ODS C18 (250 X 4.6 mm) 5mm column using Water: Methanol (50:50, v/v) pH: 4 mixture as a mobile phase. The detection was carried out at 235 nm with a flow rate of 1.0 mL/min. The retention times were 4.807 and 3.273 minutes for Miglitol and Metformine Hydrochloride, respectively. The linearity of the method was excellent over a concentration range 2.5 to 7.5μg/mL for Miglitol and 25 to 75μg/mL for Metformine Hydrochloride. The correlation coefficient was 0.997 and 0.999 for Miglitol and Metformine Hydrochloride, respectively. The limit of detection was 0.6607μg/mL and 1.740μg/mL for Miglitol and Metformine Hydrochloride, respectively. The limit of quantitation was 2.0021μg/mL and 5.2736μg/mL for Miglitol and Metformine Hydrochloride, respectively. The relative standard deviation values for repeatability, intraday precision and interday precision studies were less than 2 % and %...
Read More
Posted by admin on Nov 1, 2014 in |
When designing small molecules to interact with the targets, one should consider stereo selectivity. As considerations for exploring structure space evolve, chirality is increasingly important. Binding affinity for a chiral drug can differ for diastereomers and between enantiomers. For the virtual screening and computational design stage of drug development, this problem can be compounded by incomplete stereochemical information in structure libraries leading to a “coin toss” as to whether or not the “ideal” chiral structure is present. Creating every stereoisomer for each chiral compound in a structure library leads to an exponential increase in the number of structures resulting in potentially unmanageable file sizes and screening times. Therefore, only key chiral structures, enantiomeric pairs based on relative stereochemistry need be included, and lead to a compromise between exploration of chemical space and maintaining manageable libraries. In clinical environments, enantiomers of chiral drugs can have reduced, no, or even deleterious effects. This underscores the need to avoid mixtures of compounds and focus on chiral synthesis. Governmental regulations emphasizing the need...
Read More
Posted by admin on Nov 1, 2014 in |
A simple, rapid and precise reverse phase high performance liquid chromatographic method has been developed for simultaneous estimation of Cinnarizine and Dimenhydrinate in Tablet Dosage Form. Chromatography was performed on a PhenomenexPartisil ODS C18 (250 X 4.6 mm) 5mm column using Acetonitrile: Water (90:10) as a mobile phase. The detection of the synthetic mixture was carried out at 265 nm with a flow rate of 0.7 ml/min. The retention times were 4.3 and 5.8 minutes for Cinnarizine and Dimenhydrinate, respectively. Proposed method was validated as per ICH guidelines for linearity, accuracy, precision; specificity and robustness for estimation of Cinnarizine and Dimenhydrinate in Tablet Dosage Form and results were found to be satisfactory. The linearity of the method was excellent over a concentration range 20-100μg/ml for Cinnarizine and 40-200μg/ml for Dimenhydrinate. The correlation coefficient was 0.996 and 0.992 for Cinnarizine and Dimenhydrinate, respectively. The limit of detection was 1.62μg/mL and 2.62μg/mL for Cinnarizine and Dimenhydrinate, respectively. The limit of quantitation was 4.93μg/mL and 7.95μg/ml for Cinnarizine and Dimenhydrinate, respectively. The...
Read More
Posted by admin on Nov 1, 2014 in |
Biobatch is usually prepared for the purpose of pharmacokinetic evaluation before NDA or IND filing. There are several critical issues that one has to face during the audit process like equivalence between the Biobatch and proposed commercial production batch. During the development and scale-up of the manufacturing process, various standard operating processes have to be documented to provide link between the bio/clinical batch and commercial batch. The Biobatch is a key component of the quality assessment, regardless of whether there is a bio waiver supported by dissolution studies or a formulation comparison, or bioequivalence study. IVIVC is one of the methods accepted by regulatory authorities including USFDA and it is applied while preparing the Biobatch. Extensive pilot experiments are to be carried out before a Biobatch is prepared. This may increase the cost of production for the company. Further, even after the approval of the formulation, various pharmaceutical factors may vary and lead to inconsistencies during the production phase. Recently, to overcome these problems, several software are available. Judicious...
Read More
Posted by admin on Nov 1, 2014 in |
The author selected and developed a new simple, sensitive and reproducible spectrofluorimetric method and validated for the determination of Memantine Hydrochloride in bulk as well as pharmaceutical formulations depending on condensation of Memantine hydrochloride with 1, 2 – Naphthoquinone -4- sulphonate (NQS) in an alkaline medium to become a product with orange color. The spectrofluorimetric method involved reduction of the product with potassium borohydrate and the later measurements of fluorescent formed lessen the NQS product after excitation at 295 nm and emission wavelength at 385 nm for the spectrofluorimetric method under optimum conditions, linear relationship with best correlation coefficient 0.9999 and the linearity was detected in between the range of 0.25-1.25 µg/mL. The mean accuracy was found to be 99.57 % to 99.66 %. The intraday and interday precision was found to be 0.14-0.16 % and 0.13-0.15% respectively. The limit of detection was found to be 0.0090µg/mL and the limit of quantification was 0.0270µg/mL. Therefore this newly recommended spectrofluorimetric method is most suitable for estimation of Memantine and observed...
Read More