Posted by admin on Nov 1, 2012 in |
Starting from plastic industry, today melt extrusion has found its place in the array of pharmaceutical manufacturing processes. Melt extrusion processes are currently applied in the pharmaceutical field for the formulation of variety of dosage forms such as granules, pellets, tablets, implants, transdermal systems & ophthalmic inserts. This technology represents an efficient pathway for increasing the solubility of poorly soluble drugs. The process forms a solid dispersion where the drug is presented in an amorphous & molecularly dispersed state in a carrier. This leads to an increase in solubility, as no lattice energy has to be overcome during dissolution. Melt extrusion is considered to be an efficient technology in the field of formulation of solid dispersions to improve bioavailability with particular advantages over solvent processes. This article highlights on the technology of Hot Melt Extrusion...
Read More
Posted by admin on Nov 1, 2012 in |
This review describes the potential and, in particular, some relevant hazards associated with the use of veterinary drugs, various pharmaceuticals and industrial chemicals that have produced serious environmental risks and affected the life of people along with other animals by posing great health risks. Risk analysis regarding these problems has also been discussed with the measures to handle the problem at global level. The most contentious residues which occur in meat, milk and eggs along with the environment are antibacterial drugs, hormonal growth promoters, heavy metals and industrial chemicals that are producing potential toxic health effects that include systemic toxicity, mutations, cancer, birth defects and reproductive disorders. Systemic toxicity involves changes in the structure and function of organs and organ systems: weight change, structural alterations and changes in organ system or whole animal function. Functional effects may include changes in the lungs, liver, kidneys, cardiovascular function, brain, nervous system activity, behavior and in production of resistance to disease. Furthermore, continued monitoring and periodic reassessment of risks posed by these...
Read More
Posted by admin on Nov 1, 2012 in |
Many therapeutic agents are most effective when made available at constant rates, near the absorption sites or at the correct time of administration. Pulsatile drug delivery system is the most interesting time-specific and site-specific system. This system is designed for chronopharmacotherapy which is based on circadian rhythm. Recently a greater effort has been taken in designing delivery systems which synchronize drug delivery with circadian rhythms in order to optimize efficacy and /or minimize side effects. Pulsatile systems deliver the drug at right site of action at the right time and in the right amount. Chronotherapeutics is the discipline concerned with the delivery of drugs according to inherent activities of a disease over a certain period of time. Chronotherapy can particularly benefit patients suffering from allergic rhinitis, rheumatoid arthritis and related disorders, asthma, cancer, cardiovascular diseases, and peptic ulcer disease. This review gives an outline as to how pulsatile drug delivery systems based on circadian rhythms are...
Read More
Posted by admin on Nov 1, 2012 in |
An accurate, sensitive and precise RP-HPLC –Fluorescence method has been developed and validated for the estimation of Carvedilol Phosphate (CP) from bulk drug and Pharmaceutical Dosage form. The separation was achieved by a Brownlee analytical C18 column (250mm X 4.6mm, 5μm) in isocratic mode, with mobile phase comprises of Acetonitrile : Methanol : Buffer in proportion of 70:20:10v/v/v, buffer was 5mM Potassium Di-hydrogen Phosphate (pH 3.5 adjusted with Ortho Phosphoric Acid). The flow rate of mobile phase was 1.0ml/min and employing fluorescence detection with 280nm excitation and 340nm emission wavelengths. The retention time of Carvedilol Phosphate was 2.20 min.The calibration curve was found to be linear within the concentration range of 10ng/ml to 60ng/ml. The regression data for calibration curve shows good linear relationship with r2 = 0.990. The method was validated in accordance with the requirements of ICH guidelines. Moreover, the proposed analytical method was applied to monitor the formulation commercially...
Read More
Posted by admin on Nov 1, 2012 in |
The present study was designed to evaluate anti-hyperglycemic activity of simvastatin alone and the combination of sub therapeutic doses of simvastatin and glipizide. Hyperglycemia was induced experimentally in albino rats by subcutaneous injection of alloxan in a dose of 175 mg/kg body weight. After 72 hours of alloxan treatment, rats showing hyperglycemia (blood glucose level of 400 mg/dl and above) were included in the study. They were divided into four groups of 6 animals each (n=24). Oral administration of normal saline 0.5 ml, glipizide 2.5 mg/kg body weight, simvastatin 10 mg/kg body weight and sub therapeutic doses of both test (simvastatin 5 mg/kg body weight) and standard (glipizide 1.25 mg/kg body weight) drugs, was done respectively into each of the four groups for 30 consecutive days in order to assess the effect in terms of reduction in blood glucose level. Blood glucose was estimated on 0th, 10th, 20th, and 30th days of study in fixed time intervals. In the test group, there was a gradual fall in the blood...
Read More