Posted by admin on Feb 1, 2012 in |
Riboflavin binding protein (RfBP) was isolated from the eggs of Aquila hastate (eagle). The protein was purified in two steps, DEAE – Sepharose ion exchange chromatography and gelfilteration on Sephadex G-100. The holoprotein had an absorption spectrum characteristic of flavoproteins. The purity of the protein was judged by SDS-PAGE technique. A single band on the slab and cylindrical gel revealed that the protein was pure comparison of the mobility of RfBP with that of the standard molecular weight marker proteins suggested that RfBP from the egg white of Aquila hastate had a molecular weight close to 29...
Read More
Posted by admin on Feb 1, 2012 in |
The antibacterial activity of methanol extract of Abutilon indicum, Hygrophila spinosa and Mimosa pudica were studied by agar well diffusion method in vitro. The effect of antibacterial potential was examined against Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus cereus, Proteus vulgaris, Enterococcus faecalis, Klebsiella pneumoniae, Vibrio cholerae, Salmonella typhi and Salmonella paratyphi. The methanol extract of these medicinal plants have showed consistently significant inhibitory activity on different bacterial pathogens tested. Furthermore, the Minimum Inhibitory Concentration (MIC) studies carried out by broth dilution assay and found the MIC ranged between 0.2 to 0.9mg/ml. Overall the methanol extracts was found to be more effective. The results of the extracts were compared with the standard antibiotics...
Read More
Posted by admin on Feb 1, 2012 in |
This study assessed the level of compliance using three different methods: pill count, self report and peak expiratory flow rate, in asthmatic patients attending a secondary health care facility. Self report (using a pre-tested structured questionnaire), peak expiratory flow rate and pill count were used to assess patient’s compliance and identify the factors which may be responsible for non compliance. Measurement of peak flow rate and the pill count were done at two different occasions. The data obtained was analysed using descriptive statistics. The study showed that the patients were prescribed a range of one to four drugs: 54% (3 drugs), 32% (2 drugs), 8% (4 drugs) and 2% (1 drug). The levels of compliance were 86.57% for self report and 83.56% for pill count (p > 0.05). Reasons given for non compliance were: apparent wellness (33.31%), forgetfulness (26.67%), cost of drugs (6.67%), dysphagia (6.67%), presence of non-disturbing symptoms (6.67%), side effects (6.67%), ignorance/fear of addiction (6.67%), perceived lack of benefit from treatment (6.67%), and lethargy towards chronic medication...
Read More
Posted by admin on Feb 1, 2012 in |
This study was designed to investigate the in vitro anti-oxidant and in vitro anti-inflammatory potential of synthesized 3(Substituted) Chromen-2-one. Anti-oxidant activity has done by DPPH, NO and H2O2 free radical scavenging activity, ascorbic acid was used as a standard. Anti-inflammatory activity has done by membrane stabilization method; aceclofenac sodium was used as standard. The presence of OCH3 group in aromatic ring system of the compound prompted us to evaluate its anti-oxidant and anti-inflammatory activity. Some of the synthesized compounds which contains OCH3 group has been found to be having high anti-oxidant and anti-inflammatory activity by various in vitro...
Read More
Posted by admin on Feb 1, 2012 in |
A simple, accurate, precise and sensitive reverse phase high performance liquid chromatography (RP-HPLC) method for the determination of cefixime trihydrate and its degraded products have been developed and validated. Drug was resolved on a C18 column (waters spherisorb 25 cm × 4.6 mm, 5µm), utilizing mobile phase of sodium dihydrogen phosphate monohydrate (0.1M aqueous) pH adjusted to 2.5 with diluted orthophospharic acid (10 % aqueous) and methanol in a ratio of 3:1 respectively. Mobile phase was delivered at the flow rate of 1.0 ml/min. Ultra violet detection was carried out at 254 nm. Separation was completed within 9.75 minutes. Calibration curve was linear with correlation coefficient (r2) = 0.9996 over a concentration range 10-50µg/ml. Recovery was between 98.84, 100.25 percentage. Method was found to be reproducible with relative standard deviation (RSD) for intra and interday precision of < 1.0 over the said concentration range. The method was successfully applied to the determination of the decomposed products of cefixime trihydrate, it can be very useful and an alternate to performing...
Read More