Posted by admin on Feb 1, 2011 in |
The purpose of the study was to determine the in vitro as well in vivo efficiencies of 1% carbopol hydrogel different preparations containing the meloxicam, a cyclooxygenase-2 inhibitor anti-inflammatory drug with b-cyclodextrin. The release of plain drug was then compared with release of from trans dermal gel containing physical mixture of drug and b-cyclodextrin, inclusion complex of drug and b-cyclodextrin obtained by kneading method and in situ complex of drug and b-cyclodextrin obtained by reacting the drug and b-cyclodextrin within the gel. All solid inclusion complex abstained were then characterized by x-ray diffractrometry, infrared spectroscopy, differential scanning colorimetry and scanning electron microscopy, where as the in situ complex formation was evidenced only by release and permeation studies. Although many other derivative of cyclodextrins such as hydroxy propyl-b-cyclodextrin and methylated-b-cyclodextrin are better skin permeating enhancers but in this study b-cyclodextrin was employed because of ease of availability and low cost. Solid inclusion complex was prepared by kneading method. Gel formulations were prepared by incorporating pure drug, physical mixture, inclusion complex...
Read More
Posted by admin on Feb 1, 2011 in |
Graphite is made up of layers of carbon atoms arranged in a hexagonal lattice, like chicken wire (see fi the term nanotube is normally used to refer to the carbon nanotube, which has received enormous attention from researchers over the last few years and promises, along with close relatives such as the nanohorn, a host of interesting applications. The theoretical minimum diameter of a carbon nanotube is around 0.4 nanometers, which is about as long as two silicon atoms side by side, and nanotubes this size have been made. Average diameters tend to be around the 1.2 nanometer mark, depending on the process used to create them. Carbon nanotubes are extremely thin (their diameter is about 10,000 times smaller than a human hair), hollow cylinders made of carbon atoms. Biological systems are known to be highly transparent to 700- to 1, 100-nm near-infrared (NIR) light. It is shown here that the strong optical absorbance of single-walled carbon nanotubes (SWNTs) in this special spectral window, an intrinsic property of SWNTs,...
Read More
Posted by admin on Feb 1, 2011 in |
New 5- phenyl- 1, 3, 4- oxadiazole- 2- thiol derivative was synthesized by the ring closure reactions of benzohydrazides with carbon disulphide in presence of ethanolic KOH followed by substitution with secondary amines at 2nd position. All the newly synthesized compounds were characterized by IR, NMR and LC-MASS spectral data. Most of them were tested for their anti-inflammatory and antibacterial...
Read More
Posted by admin on Feb 1, 2011 in |
Hormonal changes during the menstrual cycle are well documented but there are very few reports on the changes in serum calcium, phosphorus and uric acid levels in various phases of the menstrual cycle. Therefore, present study was conducted on 50 healthy females in the age group of 18-35 menstruating regularly (cycle length between 25 and 35 days). The study demonstrated that serum calcium levels were significantly (p<0.001) higher in follicular phase than menstrual and luteal phases. Serum inorganic phosphorus levels decreased progressively and significantly (p<0.001) from the menstrual phase to the follicular phase and from the follicular phase to the luteal phase while serum uric acid levels were significantly (p<0.001) lower in luteal phase than the menstrual and follicular phases. These changes in calcium, phosphorus and uric acid in serum may have significance in terms of the normal reference interval, hence necessitate small but significant alterations to the normal reference interval for these analytes in menstruating...
Read More
Posted by admin on Feb 1, 2011 in |
A simple, precise, specific and accurate reverse phase HPLC method has been developed for the determination of Ritonavir in bulk and pharmaceutical dosage forms. The chromatographic separation was achieved on Symmetry C18 (4.6 x 100mm, 3.5 μm) column using a mixture of Buffer: Acetonitrile (50:50) as the mobile phase at a flow rate 1.0 ml/min. Linearity was observed in concentration range of 50-150μg/ml. The retention time of Ritonavir was 5.1 min. The analyte was monitored using UV detector at 239 nm. Results of analysis were validated statistically and by recovery studies. The method was validated according to the ICH guidelines with respect to specificity, linearity, accuracy, precision and...
Read More